SY-FPS101 Aramid firefighting suits protect the firefighters active in front of the fire line, and are used to protect the upper and lower torso, head and neck, arms and legs. However, the protection range does not include the head, hands and Feet, it is not only indispensable fire emergency site, but also to protect the firefighters body from fire damage equipment. Therefore, to adapt to fire rescue activities firefighting service is particularly important.
(1)Fire Fighting
(2)Emergency Rescue
(1)Four-layer design, the material is Kevlar, carbonized when it is burned, will not drop;
(2)With flame retardant, moisture-proof breathable, heat radiation, anti-static, wear-resistant properties
(3)Chest with walkie talkie bags, flashlight fixtures parts;
(4)Clothing shoulder, elbow, wear-resistant layer of clothes pocket;
(5)Bib pants, pants plus wear layer;
(6)Clothes hem, Kujiao inner layer of water stop layer;
(7)Reflective tape preparation area in line with the requirements of EN469;
(8)It can work normally in the environment of 250 ℃ for a long time, and begin to carbonize when the temperature reaches 350 ℃.
(9)There will not be any change after burning under the lighter for 5 seconds. After 5 seconds, it will begin to carbonize, but it will not be ignited. When the lighter burns for a period of time, there may be a little spark, but the spark will leave the source of ignition Disappear immediately
Cloth Layer | Fabric Construction |
Outside Layer | Structure: Cross Grain Element: 93% Meta-Nomex, 5% Para-Nomex, 2% Anti-Static Fiber Gram Weight: 210g/㎡ Breadth: 58/60” Color: Dark Blue |
Water-Resisting Ventilating Layer | Structure: Nomex Felt PTEE Coated Gram Weight: 105g/㎡ Breadth: 58/60” |
Thermal Insulating Layer | Element: Nomex Gram Weight: 150g/㎡±10 g/㎡ Breadth: 58/60” |
Comfort Layer(lining layer) | Structure: Tabby Element: 50% Meta-Nomex, 50% Flame Resisting Viscose Gram Weight: 120g/㎡ Breadth: 58/60” |